-40°C~+70°C
IP66;IP67;IP68
Ex d IIC T4;Ex d IIB T4
SIL2/SIL3
● Servo pump control design, high reliability, low energy consumption, low maintenance cost | ● Modular design, flexible combination of different specifications to meet Various requirements |
● Intelligent electronic control, visual interface, rich functions to meet various process requirements | ● Independent hand pump module for easy commissioning and emergency operation |
● Hydraulic power transmission, large torque output, high transmission efficiency, reliable over-torque protection | ● Flexible installation method, which can be installed as a whole or separately, adapting to complex site conditions |
● Reliable protection and explosion-proof performance | ● Multiple power supplies are available, wide ambient temperature adaptation range |
● Integrated Model design, self-contained power and oil source, small size, no external hydraulic piping required | ● Fully electrically isolated signal interface |
● ON-OFF or control Type can select, linear or rotary type can select | ● Remote control jog, remote control long-distance and remote control analog adjustment function |
● Lock position when stop running or power is off | ● Full open hold, full close hold, position hold function |
● Local jog and Local on-off functions | ● Full-open enhancement and full-close enhancement |
● Fault self-diagnosis function | ● PST partial stroke test function |
● On-site installation verification positioning and parameter setting function | ● Full-open, full-close and valve position status feedback |
● Programmable segment speed control function | ● Fault alarm and reset function |
● Power supply (optional):DC: 24V;48V;72V
AC(50/60Hz):110VAC/1P;220VAC/1P;
380VAC/3P;400VAC/3P;415VAC/3P |
● Control mode (optional): On/Off type modulate Type (including On/Off type function)
Control signal: dry contact or 24VDC 4-20mA or 20-4mA Status feedback: dry contact dry contact Valve position feedback: 4-20mA active 4-20mA active |
● Torque range (Rotary type): 150Nm~250,000Nm | ● Basic error: ≤0.2% ≤0.5% |
● Thrust range (Linear Type): 16KN~1,250KN | ● Repeatability: ≤0.2% ≤0.5% |
● Fault reset (optional): IP66; IP67; IP68 | ● Adjust deadband: 0.2% 0.5% |
● Protection Level (optional): IP66; IP67; IP68 | ● Action response time: ≤ 0.5s |
● Explosion-proof Level(optional): ExdIIBT4; ExdIICT4 | ● Ambient temperature (optional): -20 °C to +70 °C; -40 °C to +70 °C |
● Control accuracy (optional): 0.2 level 0.5 level | ● Electrical interface: NPT3/4(F), NPT1(F)*2 |
NOTE-1
Figure 1 and Figure 2 above show the wiring diagram when the mode knob in the REMOTE position. The local OPEN/CLOSE/CAL button is invalid. Figure 1 is the 24VDC using the actuator. Figure 2 shows the 24VDC outside the actuator.
NOTE-2
When the IN-STOP distal normally closed button is open (pressed), it is in LATCH mode. Press and hold OPEN or CLOSE to control the valve action.
NOTE-3
THREE mode when the IN-STOP distal normally closed button is closed (not pressed)
The THREE mode divides the OPEN and CLOSE action processes into three intervals, and each of the three sections sets the speed, which can play the role of mitigating impact and waterproof hammer.
The interval setting, the motion speed, and the stop time are all set in the user menu.
Click the OPEN button. The actuator will always run to the F/O state.
Pressing the CLOSE button will cause the actuator to run to the F/C state.
When the STOP button is pressed during operation, the actuator stops running.
NOTE-4
SEL switch for selecting digital control (DI) or analog control (AI)
In AI mode, the actuator inputs a 4-20 mA analog signal according to the Al terminal {corresponds to 0-100% of the stroke). Drive the valve to the appropriate position at the set speed.
In the Al mode. Press the remote STOP button or press the local STOP button or switch the model knob to stop the actuator and issue a forced stop alarm message.
The opening feedback signal is 4-20 mA corresponding to 0-100% of the stroke.
NOTE-5
The EMG signal is the interlock signal access terminal and only works in the REMOTE state. The EMG signal is a continuous signal. When the EMG signal is valid, the actuator performs the valve opening or closing action according to the setting requirements, and is used as the interlock control.
AT | 1 | 0 | -01 | -M | E | -90° | -xxxx |
AERO Electro-Hydraulic Actuator |
1: Basic type | 0: Rotation 1: Linear |
Torque series Thrust series |
M:Modulate O:ON/OFF |
E: Explosion Protection W: Waterproof |
Rotation ° Stroke mm |
Special specifications |
model |
Rated torque NM | 90° maximum running speed (S) | Remarks |
|||||||
Power module | S1 | S2 | A | B | C | E | F | |||
Maximum power consumption | 200W | 300W | 600W | 1.2KW | 3KW | 6KW | 8KW | |||
AT10-00 | 150 | 4.0 | 3.0 | 2.0 | / | / | / | / | ||
AT10-01 | 500/800 | 16.8 | 12.5 | 7.0 | 4.2 | / | / | / | ||
AT10-02 | 1200/1500 | 27.3 | 20.2 | 11.0 | 6.4 | 2.9 | / | / | ||
AT10-03 | 2000/2500 | 48.4 | 35.6 | 19.0 | 10.7 | 4.5 | / | / | ||
AT10-04 | 3500/4000 | / | 54.8 | 29.0 | 16.1 | 6.4 | / | / | ||
AT10-05 | 5000/6300 | / | / | 41.0 | 22.5 | 8.7 | / | / | ||
AT10-06 | 8000/10000 | / | / | 61.0 | 33.3 | 12.6 | / | / | ||
AT10-07 | 16000 | / | / | 101 | 54.8 | 20.3 | 10.5 | / | ||
AT10-08 | 22000 | / | / | 141 | 76.3 | 28.0 | 14.1 | / | ||
AT10-09 | 32000 | / | / | 201 | 109 | 39.6 | 19.8 | / | ||
AT10-10 | 45000 | / | / | 281 | 152 | 55.1 | 27.3 | 22 | ||
AT10-11 | 64000 | / | / | 401 | 216 | 78.2 | 38.6 | 30.6 | ||
AT10-12 | 80000 | / | / | / | 270 | 97.5 | 48.0 | 37.9 | ||
AT10-13 | 125000 | / | / | / | 431 | 155 | 76.3 | 60.1 | ||
AT10-14 | 250000 | / | / | / | / | 310 | 152 | 129 |
AT | 1 | 0 | -01 | -M | E | -200 | -xxxx |
AERO Electro-Hydraulic Actuator |
1: Basic type | 0: Rotation 1: Linear |
Torque series Thrust series |
M: Modulate O: ON/OFF |
E: Explosion Protection W: Waterproof |
Rotation ° Stroke mm |
Special specifications |
model |
Rated thrust kN | Maximum operating speed (mm/S) | Remarks |
|||||||
Power module | S1 | S2 | A | B | C | E | F | |||
Maximum power consumption | 200W | 300W | 600W | 1.2KW | 3KW | 6KW | 8KW | |||
AT11-00 | 16 | 7.72 | 10.56 | 20.3 | 37.78 | / | / | / | ||
AT11-01 | 32 | 3.86 | 5.28 | 10.16 | 18.89 | / | / | / | ||
AT11-02 | 40 | 3.09 | 4.23 | 8.13 | 15.11 | / | / | / | ||
AT11-03 | 50 | / | 3.25 | 6.25 | 11.6 | 32.3 | / | / | ||
AT11-04 | 80 | / | 2.03 | 3.91 | 7.27 | 20.2 | / | / | ||
AT11-05 | 100 | / | / | 3.25 | 6.05 | 16.84 | / | / | ||
AT11-06 | 125 | / | / | 2.40 | 4.47 | 12.45 | / | / | ||
AT11-07 | 160 | / | / | 1.95 | 3.63 | 10.1` | / | / | ||
AT11-08 | 200 | / | / | 1.63 | 3.02 | 8.42 | 17.2 | / | ||
AT11-09 | 250 | / | / | 1.30 | 2.42 | 6.73 | 13.8 | / | ||
AT11-10 | 320 | / | / | / | 2.25 | 6.27 | 12.8 | 16.3 | ||
AT11-11 | 400 | 1.80 | 5.02 | 10.2 | 13.0 | |||||
AT11-12 | 500 | / | / | / | / | 4.01 | 8.2 | 10.4 | ||
AT11-13 | 630 | / | / | / | / | 3.19 | 6.5 | 8.3 | ||
AT11-14 | 800 | / | / | / | / | 2.51 | 5.1 | 6.5 | ||
AT11-15 | 1000 | / | / | / | / | 2.01 | 4.1 | 5.2 | ||
AT11-16 | 1250 | / | / | / | / | 1.61 | 3.2 | 4.1 |