Normal: -20~70℃
Low: -40~70℃
IP66;IP67
ExdIIBT4; ExdIICT4
SIL2/SIL3
| ● Functional safety level up to SIL2, SIL3 | ● Modular design, flexible combination of different specifications to meet load requirements |
| ● Intelligent electronic control, visual interface, rich functions, to meet various process requirements | ● Independent hand pump module for easy commissioning and emergency operation |
| ● Hydraulic power transmission, large output torque, high transmission efficiency, reliable over-torque protection | ● Flexible installation method, which can be installed as a whole or separately, adapting to complex site conditions |
| ● Independent ESD loop for higher reliability | ● Reliable protection and explosion-proof performance |
| ● Integrated and integrated design, self-contained power and oil source, small size, no external hydraulic piping required | ● Fully electrically isolated signal interface |
| ● Piston accumulator storage power, low power hydraulic oil pump, real-time monitoring and supplement Accumulator pressure, one oil filling, system pressure is not less than 30 days | ● A variety of power supply options, wide ambient temperature adaptation range |
| ● Fully enclosed hydraulic system for high pollution and high reliability |
| ● Remote control type and ESD type optional | ● Remote control jog, remote control and long-distance function |
| ● On, off, ESD speed independently adjustable | ● Full open hold, full hold, position hold function |
| ● Optional accumulator single stroke and multi-stroke operation | ● Full-open strengthening, full-off strengthening function |
| ● Fault self-diagnosis function | ● PST partial stroke test function |
| ● On-site installation verification positioning and parameter setting function | ● Full-open, full-close and valve position status feedback |
| ● On-the-spot, on-the-spot function | ● Fault alarm and reset function |
| ● Switch with lock function |
|
● Power supply (optional): DC: 24V; 48V; 72V
AC (50/60Hz): 110VAC/1P; 220VAC/1P; 380VAC/3P; 400VAC/3P; 415VAC/3P |
● Control method: Control signal: dry contact or 24VDC Status feedback: dry contact Valve position feedback: 4-20mA active |
| ● Torque range (Rotary type): 2,000Nm~250,000Nm | ● Control accuracy (optional): Basic error: ≤0.5% Repeatability: ≤0.5% |
| ● ESD solenoid valve power supply: 24VDC | ● Action response time: ≤0.5S |
| ● ESD function (optional): Full off; Full on | ● Ambient temperature (optional): -20°C+70°C; -40°C to +70°C |
| ● Protection level (optional): IP66; IP6 | ● Electrical interface: NPT3/4(F), NPT1/2(F)*2 |
| ● Explosion-proof Level (optional): ExdIIBT4; ExdIICT4 |



| AT | 6 | 0 | -KE | -32000 | -xxxx |
| Aero Electro-Hydraulic Actuator | series | 0: Rotation | KE: ESD type KC: Cut-Off type |
Output Torque Nm |
Special specifications |
| model |
Rated torque NM |
Compatible power module / maximum power consumption | |||||
| S1 | S2 | A | B | C | E | ||
| 200W | 300W | 600W | 1.2KW | 3KW | 6KW | ||
| AT60-2000 | 2000 | ★ | ★ | ★ | ★ | ||
| AT60-3500 | 3500 | ★ | ★ | ★ | ★ | ||
| AT60-6300 | 6300 | ★ | ★ | ★ | ★ | ||
| AT60-8000 | 8000 | ★ | ★ | ★ | |||
| AT60-12000 | 12000 | ★ | ★ | ★ | |||
| AT60-16000 | 16000 | ★ | ★ | ★ | ★ | ||
| AT60-22000 | 22000 | ★ | ★ | ★ | ★ | ||
| AT60-32000 | 32000 | ★ | ★ | ★ | ★ | ||
| AT60-45000 | 45000 | ★ | ★ | ★ | ★ | ||
| AT60-63000 | 63000 | ★ | ★ | ★ | ★ | ||
| AT60-80000 | 80000 | ★ | ★ | ★ | ★ | ||
| AT60-120000 | 120000 | ★ | ★ | ★ | ★ | ||
| AT60-160000 | 160000 | ★ | ★ | ★ | |||
| AT60-200000 | 200000 | ★ | ★ | ★ | |||
| AT60-250000 | 250000 | ★ | ★ | ★ | |||